Building
1. Site requirements:
Parking Fire access Vehicle loading Driving/turning radius Fire hydrant/water supply/post indicator valve (PIV) Set back/separation (assumed property lines) Location of specific tanks, water lines and sewer lines
2. Occupancy group and special occupancy requirements shall be determined.
3. Minimum type of construction shall be determined (see Table 503 ).
4. Fire-resistant construction requirements shall include the following components:
Fire-resistant separations Fire-resistant protection for type of construction Protection of openings and penetrations of rated walls Fire blocking and draftstopping and calculated fire resistance
5. Fire suppression systems shall include:
Early warning smoke evacuation systems Schematic fire sprinklers Standpipes Preengineered systems Riser diagram Same as above.
6. Life safety systems shall be determined and shall include the following requirements:
Occupant load and egress capacities Early warning Smoke control Stair pressurization Systems schematic
7. Occupancy load/egress requirements shall include:
Occupancy load Gross Net Means of egress Exit access Exit Exit discharge Stairs construction/geometry and protection Doors Emergency lighting and exit signs Specific occupancy requirements Construction requirements Horizontal exits/exit passageways
8. Structural requirements shall include:
Soil conditions/analysis Termite protection Design loads Wind requirements Building envelope Structural calculations (if required) Foundation Wall systems Floor systems Roof systems Threshold inspection plan Stair systems
9. Materials shall be reviewed and shall at a minimum include the following:
Wood Steel Aluminum Concrete Plastic Glass Masonry Gypsum board and plaster Insulating (mechanical) Roofing Insulation
10. Accessibility requirements shall include the following:
Site requirements Accessible route Vertical accessibility Toilet and bathing facilities Drinking fountains Equipment Special occupancy requirements Fair housing requirements
11. Interior requirements shall include the following:
Interior finishes (flame spread/smoke development) Light and ventilation Sanitation
12. Special systems:
Elevators Escalators Lifts
13. Swimming pools:
Barrier requirements Spas Wading pools
Electrical
1. Electrical:
Wiring Services Feeders and branch circuits Overcurrent protection Grounding Wiring methods and materials GFCIs
2. Equipment
3. Special occupancies
4. Emergency systems
5. Communication systems
6. Low voltage
7. Load calculations
Plumbing
1. Minimum plumbing facilities
2. Fixture requirements
3. Water supply piping
4. Sanitary drainage
5. Water heaters
6. Vents
7. Roof drainage
8. Back flow prevention
9. Irrigation
10. Location of water supply line
11. Grease traps
12. Environmental requirements
13. Plumbing riser
Mechanical
1. Energy calculations
2. Exhaust systems:
Clothes dryer exhaust Kitchen equipment exhaust Specialty exhaust systems
3. Equipment
4. Equipment location
5. Make-up air
6. Roof-mounted equipment
7. Duct systems
8. Ventilation
9. Combustion air
10. Chimneys, fireplaces and vents
11. Appliances
12. Boilers
13. Refrigeration
14. Bathroom ventilation
15. Laboratory
Gas
1. Gas piping
2. Venting
3. Combustion air
4. Chimneys and vents
5. Appliances
6. Type of gas
7. Fireplaces
8. LP tank location
9. Riser diagram/shutoffs
Demolition
1. Asbestos removal |